Open
operation in 3D.
function call:
[out_img1]=vsg('Open3D',in_img1,connected);
Arguments:
in_img1
-
input image, a DICOM image.
connected
– an integer specifying whether 6 or 26 connected is used.
Description:
out_img1
– a DICOM image. Each value of the DICOM image is the result of first
doing a 3D erode, followed by a 3D dilate operation.
Example:
[filename, chosenDirectory] = uigetfile('*.dcm',
'Pick an M-file');
filePath = [chosenDirectory filename];
stackOfImages=vsg('DICOMRead',filePath);
%4D array of data
[out_img1]=vsg('Open3D',stackOfImages,6);
1. For
2. Dicom images
require XMedCon software (version xmedcon-0.10.5-1-win32).
3. DICOM data must
be in a separate folder.